(631) 643-1483
Request a QuoteService Request

Model 956, Marker Light

Model 956, Marker Light

SKU: 956-P21926Categories: Exterior Lighting, LED Marker Lights

Matrix Railway PAR46 LED Marker Lights are built to meet the stringent rail specifications and rugged environment, and are listed in FRA Approved List.

 

$0.00

Product Details
Specifications

Matrix Railway LED Taillights/Marker Lights incorporate a low profile design and an advanced wide range power supply.  The operating input voltage range of from 22Vdc to 95Vdc.  This voltage range covers most of industry’s voltage standards such as 24 Vdc, 37.5 Vdc, & 74 Vdc +/- 20%.

The marker light circuitry designed with 6 redundant LED circuits so that in case of an LED failure, operation and maximum safety is maintained throughout entire car daily run.

The Marker Light’s regulators eliminate EMI/EMC emissions, and its input protection circuitry protects against Over/Under voltage, Over/Under current, reversed voltage, and fast transients.  Matrix Railway Marker Light is provided with a 5 Year Warranty.

Electrical Specifications

Nominal Input Voltage 24VDC/37.5 VDC/74VDC
Nominal Input Voltage Range
  • 18 ‐ 30VDC
  • 20 – 50 VDC
  • 60 – 95 VDC
No. of Independent Channels 7 LED Channels
Power 23 Watts
Input Protection Reverse Voltage Protection
High / Low Voltage Protection
Spike and Transient Protection
Warranty 5 Years

Photometric Specifications

Wavelength-Dominant 624 nm
Luminous Intensity 200 Cd
Number of LED 98 LEDs
FRA Approved 49 CFR 221.14 Standard

Mechanical Specifications

Size PAR46
Connections Rear Studs, #8-32×3/8, Brass Nickel Plated
Mount Fixture

EMI/EMC Compliance Standards

EMI/EMC 61k Series
Electrostatic Discharge IEC 61000‐4‐2
Radio Frequencies‐Enclosure IEC 61000‐4‐3
Fast Transients Burst‐Power Ports IEC 61000‐4‐4
Fast Transient Burst – Signal Ports IED 61000‐4‐4 2kV
Surges – Power Ports IED 61000‐4‐5
Conducted Immunity, Power Ports IEC 61000-4-6
Pwr Port and Enclosure – Emissions Tests CISPR11 Group 1 Class A

Environmental Compliance Standards

Shock & Vibration, and Bump Test IEC 61373
Operating Temperature IEC 60068‐2‐14
Cooling Test, ‐40 Deg C (96Hrs) IEC 60068‐2‐1
Dry Heat Test, 85 Deb C (96 Hrs) IEC 60068‐2‐2
Damp Heat Test, 25 Deg C t0 57 Deg C (37Hrs) NYCTA Requirement
Flammability, Smoke Emission and Toxicity ASTM E162
ASTM E662
BSS7239

 

View Data Sheet